Recent Comments

    mPro400GC Software Version 1.5.0 released

    New Features / Enhancements:

    • Screen Reorganisation: Removed mPro button and unified TME and mPro GUI
    • Multi-Tool Group – Redesign Screens according to style guidelines
    • Maintenance Counters functionality
    • 99 Linking Groups can be parameterized
    • Enhanced traces configurable per tool group
    • Support of ToolsNet with traces
    • Speed ramps programmable
    • Number of bitmaps for visualization set to 40
    • FTP / SAMBA now also works in Application mode
    • Load and save single applications as XML
    • More than 80 bytes per group in byte area
    • IPM Protocol
    • CPS_READY Input implemented
    • Untightened Archive Entries (SKIP) – Results of non-tightening
    • Fast trace transmission
    • Open Protocol:
      • Support of MID 250-255
      • Channel IDs configurable
    • Back-off application configurable
    • CSV Export for all stages from HD Archive
    • Support of TRASYS protocol
    • New features for I-Wrench:
      • CCW and Seq. 63
      • More than 20 steps in Linking Group supported
      • multiple barcodes support
      • Seq. 30+50+63 trigger torque configurable
      • BLOC Angle, short and long timeout configuration
      • Application/Linking Group selection by socket head
    • New features for LiveWire tools:
      • Manual Application/Linking Group selection on tool

     

    Bug fixes:

    Number Name CQA
    PRR-00312 Speed ramps not adjustable 0926
    PRR-02583 Various issues with torque calibration factor 20000 Nm 1471
    PRR-02548 CSV-FTP loses results if rundown results have same timestamp
    PRR-02589 Schraube – Cycle time higher than 100 ms 1113
    PRR-02799 FTP-Samba – Seq. 30 limits used for Seq. 11
    PRR-02940 LiveWire tools – use of single WIFI Channel not functional 1871
    PRR-02974 OK if in limits function not translated
    PRR-02978 Timer for output signals not functional if Tool 1 is not installed
    PRR-03095 Workaround for FLT error when stopping spindles is required
    PRR-03137 I-Wrench BLOC error calculation needs to be improved
    PRR-03217 Evaluation torque for Back-off with LiveWire tools does not work
    PRR-03232 Ofmpro crash in case of barcodes including percent characters
    PRR-03445 Tool is locked by output timer although function not activated 2906
    PRR-03685 No communication for TorqueNet with new TcpClient
    PRR-03690 Application dropdown is not updated on Runscreen 3176
    PRR-03780 Error by change of tightening point at Visualization screen
    PRR-03835 Batch activation does not work properly for LiveWire tools and Open Protocol
    PRR-03841 Data not transmitted with big traces (TorqueNet and ToolsNet)
    PRR-03885 MID0035 Job info does report wrong job status
    PRR-03902 Wrong applications in applications dropdown in Runscreen with multi-tool group
    PRR-04034 Disable LiveWire tools with OP MID0042 not functional

    See mPro400GC page.

    mPro400GC Software Version 1.4.12 released

    Bug fixes:

    Number Name CQA
    PRR-03780 Error when change position point in picture
    PRR-03835 Batch activation does not work properly for LiveWire and OP
    PRR-03841 Data not transmitted with big traces
    PRR-03880 OK and NOK set at once if Sequence 46 is used with less than 9°
    PRR-03884 MID 128 sends no answer
    PRR-03972 Process Schraube crash at activation of Manual Mode in case no I-Wrench is installed

     

    See mPro400GC page.

    mPro400GC Software Version 1.4.10 released

    Bug fixes:

    Number Name CQA
    PRR-03706 Results out of order with I-Wrench with bad wireless connection 2894

    See mPro400GC page.

    mPro400GC Software Version 1.4.9 released

    Bug fixes:

    Number Name CQA
    PRR-03690 Application dropdown is not updated on Runscreen 3176
    PRR-07710 OpenProtocol workflow too slow with LiveWire Tools

    See mPro400GC page.

    mPro400GC Software Version 1.4.8 released

    Bug fixes:

    Number Name CQA
    PRR-03456 Wrong Batch Position displayed and transmitted

    See mPro400GC page.

    mPro400GC Software Version 1.4.7 released

    Bug fixes:

    Number Name CQA
    PRR-03440 Job mismatch with serial scanner and scan step for battery tool 2894

    See mPro400GC page.

    mPro400GC Software Version 1.4.6 released

    Bug fixes:

    Number Name CQA
    PRR-03276 External Application Select not functional with I-Wrench 2573
    PRR-03281 Endless loop with MID52 and MID 18
    PRR-03290 Rundown not possible in Manual Mode
    PRR-03291 Could not enter scan PartId step or barcode step manually and via Fieldbus 2641
    PRR-03320 MID 61 too slow
    PRR-03346 Different VIN transmission to CSV-SAMBA
    PRR-03359 I-Wrench does not work with Torque Multiplier
    PRR-03361 OP MID 42 and MID 43 with I-Wrench does not work with fast commands
    PRR-03363 No Job loaded to TMA after leaving Manual mode
    PRR-03366 OP Job select MID38 too slow
    PRR-03373 Scanner LiveWire Tool is not activated in Manual Operation mode part ID
    PRR-03425 OP MID-0127 Linking Group gets reselected immediately when not in Runscreen

    See mPro400GC page.

    mPro400GC Software Version 1.4.5 released

    Bug fixes:

    Number Name CQA
    PRR-03222 Tool not locked if invalid bitmask is selected

     

    See mPro400GC page.

    mPro400GC Software Version 1.4.4 released

    New Features / Enhancements:

    • OpenProtocol: New setting to allow or disallow Linking Group termination with MID0038
    • OpenProtocol: New setting for reset Batch size to zero on connection loss
    • Tightening: Evaluation Torque setting to ignore all results below this value (per tool group)
    • Data Export: Stage results selectable
    • Data Export: Decimnal separator configurable

    Bug fixes:

    Number Name CQA
    PRR-02838 MID0410 – For auto disable request no ACK or NAK response is received
    PRR-03064 Deleting application in Matrix tab is not deleting application information completely 2088
    PRR-03090 Gradient values are populated in export of Seq. 32 and no PVT value available
    PRR-03108 Differences on serial Interface with v1.4.0 to 1.4.3 2356
    PRR-03109 Barcode scan step configured from mPro linking screen saves only 16 characters
    PRR-03110 Five-decimal values for Brake Rope Adjustment parameters are changed unintentionally
    PRR-03113 Skips of a linking step when scan of barcode step with different tool is done
    PRR-03138 MID0019 – Set Batch is accepted even though batch is inactive for application
    PRR-03140 Terminology for Linking Group parameters not used consistently 2383
    PRR-03169 Tool data for Livewire tools not always available when user acceptance is needed 2358

    See mPro400GC page.

    mPro400GC Software Version 1.4.3 released

    New Features / Enhancements:

    • Support for multiple serial scanners connected to one serial port. A prefix can be assigned to each tool to distribute barcodes from multiple scanners to multiple tools.
    • Support for one serial scanner for multiple tools
    • EtherNet/IP Beacon-based DLR module supported

    Bug fixes:

    Number Name CQA
    PRR-02991 Duplicate Results from I-Wrench
    PRR-02850 Part ID change during rundown causes multiple results in Archive 1744
    PRR-03008 FEP: MID 0013: Batch size transmitted wrong
    PRR-02980 Could not setup output timers if tool group #1 not installed
    PRR-03033 Customize settings for unexpected barcodes
    PRR-03009 Visualization text of the linking step not displayed the tool display
    PRR-03010 Cannot use tools after startup with Linking Screen as startup visualization
    PRR-02987 Part ID entered through keyboard is not accepted in Ext Application mode
    PRR-02990 The Tool constants screen does not accept high angle factors
    PRR-02939 For X LiveWire models it is not possible to set the Wireless channel 1870